GORE Viabil® BILIARY ENDOPROSTHESIS
With Exclusive Pull-Line Deployment
Crafted of proprietary design and material, the GORE VIABIL® Biliary Endoprosthesis has revolutionized the palliation of symptoms caused by malignant biliary obstruction by presenting advancements in patency rates, demonstrated minimal migration and unparalleled conformability in tortuous anatomies.
Now, with the recent introduction of Pull-Line Deployment technology, this groundbreaking delivery system presents ease of use and enhances the physician’s control and accuracy in biliary stent placement. A pull of the deployment knob unknots the double-layered PTFE braid that attaches the stent to the delivery catheter and delivers the stent precisely where positioned.
The GORE VIABIL® Biliary Endoprosthesis is a flexible fully covered, self expanding metal stent constructed from nitinol and an integrated ultra-thin, non-porous ePTFE/FEP inner lining. The stated stent length on the catheter equals the measurement of the delivered stent. There is no foreshortening.
The GORE VIABIL® Biliary Endoprosthesis is available in a full range of lengths and diameters with both drainage side holes and a no-holes configuration.
Click here to request more information.
GORE VIABIL® Biliary Endoprosthesis
- Unique non-porous ePTFE*/FEP** liner
Resists bacterial colonization and bile occlusion
Prevents tissue attachment or tumor ingrowth
Facilitates longer and higher patency rates***
- Completely lined, end-to-end
Minimal metal interaction with bile duct or gastric juices
Minimal potential for tumor ingrowth or epithelialization at the ends
- Soft terminated wire ends
No mid-mucosal penetration of wires
- Flexible, covered anchoring fins
Minimal stent migration***
Prevents tissue encapsulation
- Branch drainage side wall holes and no-holes configurations
Allows 2 cm of device placement over side branch
- Geometric Nitinol construction
Flexible and conformable
Provides high radial strength
No fore-shortening
* Expanded polyetraflourethylene
** Flourinated ethylene propylene
*** Data on file

Pull-Line Deployment
- Ultra-thin, tubular filament pull-line
Unfurls the stent as the interlocking braid is pulled
- Proprietary, curved tip
Navigates challenging biliary anatomy and transitions for smoother catheter advancement and placement
- Ergonomic hub
Simple twist to unlock and deploy
- Accurate positioning
Promotes a seamless, coordinated deployment process between physician and assistent
- Gradual, controlled deployment
Intentional, incremental release of the biliary endoprosthesis
Offers an easy to use alternative to traditional push/pull deployment systems
| |
 |
 |
Turn the hub to unlock the deployment system |
Pull steadily to deploy the endoprosthesis |
|
| |
 |
| |